Distribution spare transformers and optimization of the location of mobile transformers

Document Type : Original Article

Authors

School of advanced technologies, Iran University of Science and Technologies, Tehran, Iran

10.22059/ses.2023.363032.1038

Abstract

In order to increase the stability of electricity supply in distribution systems, this article has determined the number of transformers needed in the warehouse and their storage location. To ensure reliability in distribution substations, spare transformers are required in each substation. If there is no spare transformer in a post, the fault of the transformer may lead to disconnection of the load connected to it. On the other hand, having a spare transformer at each post would be very costly. For this reason, in this article, the problem of determining the location of spare transformers will be discussed. For this purpose, the desired cost function is considered according to the distance function, and three functions of Euclidean distance, squared Euclidean distance and direct distance are used. What is searched for is a place that can minimize the determined total cost function. For this purpose, a combined method (Markov and Monte Carlo) has been used to model transformer maintenance and then to determine the optimal location of spare transformers, and Matlab software optimization algorithm has been used for simulation. The proposed model has been implemented in a 33-bus IEEE network and it can be seen that the location of the spare transformers also changes with the change in the importance of the load and this change is more intense in the direct distance method.

Keywords


[1].          R. A. El-Aal, K. Helal, A. Hassan, and S. Dessouky, "Prediction of Transformers Conditions and Lifetime Using Furan Compounds Analysis," IEEE Access, vol. 7, pp. 102264-102273, 2019.
[2].          M. Sedaghati and R. Dashti, "A New Model for Assessment and Optimization of Number of Spare Transformers and Their Locations in Distribution Systems," Iranian Journal of Electrical & Electronic Engineering, vol. 11, no. 4, p. 319, 2015.
 
[3].          A. E. Abu-Elanien and M. Salama, "Asset management techniques for transformers," Electric power systems research, vol. 80, no. 4, pp. 456-464, 2010.
[4].          R. Billinton, M. Fotuhi-Firuzabad, and S. Aboreshaid, "Power system health analysis," Reliability Engineering & System Safety, vol. 55, no. 1, pp. 1-8, 1997.
[5].          R. Allan, R. Billinton, A. Breipohl, and C. Grigg, "Bibliography on the application of probability methods in power system reliability evaluation: 1987-1991," IEEE Transactions on Power Systems, vol. 9, no. 1, pp. 41-49, 1994.
[6].          R. Ghajar and R. Billinton, "A Monte Carlo simulation model for the adequacy evaluation of generating systems," Reliability Engineering & System Safety, vol. 20, no. 3, pp. 173-186, 1988.
[7].          M. Taghi Tahooneh and R. Dashti, "A new model for calculating rational failure rates based on network assets worth," International Journal of System Assurance Engineering and Management, vol. 13, no. 5, pp. 2221-2233, 2022.
[8].          J. M. Nahman and M. R. Tanaskovic, "Probability models for optimal sparing of distribution network transformers," IEEE Transactions on Power Delivery, vol. 24, no. 2, pp. 758-763, 2009.
[9].          M. P. Marbun, N. I. Sinisuka, and N. Hariyanto, "The use of Markov Chain method to determine spare transformer number and location," International Journal of Electrical and Computer Engineering, vol. 9, no. 1, p. 1, 2019.
[10].        G. Hamoud, L. Lee, and S. Faried, "Spare Assessment of Distribution Power Transformers using Three Markov Models," in 2018 IEEE International Conference on Probabilistic Methods Applied to Power Systems (PMAPS), 2018: IEEE, pp. 1-5.
[11].        A. M. L. da Silva, J. G. de Carvalho Costa, and A. A. Chowdhury, "Probabilistic methodologies for determining the optimal number of substation spare transformers," IEEE Transactions on Power Systems, vol. 25, no. 1, pp. 68-77, 2009.
[12].        G. A. Hamoud, "Reliability Assessment of Distribution Stations Considering Spare Transformer Sharing," IEEE Transactions on Power Systems, 2023.
[13].        G. A. Hamoud, "Reliability Assessment of Distribution Power Transformers Considering Load Transfer Capability," IEEE Transactions on Power Systems, vol. 38, no. 2, pp. 1655-1662, 2022.
[14].        G. Hamoud, F. Qureshy, A. Elen, and L. Lee, "Assessment of high voltage auto-transformer spare requirements in bulk transmission systems," in IEEE Power Engineering Society General Meeting, 2004., 2004: IEEE, pp. 434-439.
[15].        G. Hamoud, "Cost/benefit analysis for use of mobile unit substations in customer delivery systems," in 2006 IEEE Power Engineering Society General Meeting, 2006: IEEE, pp. 1-5.
]16.[       شقاقی, ایدین, and دشتی, "بهینه‏ سازی اقتصادی مدیریت خاموشی در شبکه‏‏های توزیع برق," فصلنامه سیستم‏های انرژی پایدار, vol. 2, no. 1, pp. 19-34, 2022.
[17].        M. Khazaee, R. Zahedi, R. Faryadras, and A. Ahmadi, "Potential assessment of renewable energy resources and their power plant capacities in Iran," Glob J Ecol, vol. 7, no. 2, pp. 060-071, 2022.
[18].        R. Zahedi, s. gitifar, and A. Ahmadi, "Technical-economic feasibility of designing a 10 MW solar power plant of KavirTire Company in Birjand city of South Khorasan province using RET Screen software," (in en), Journal of Renewable and New Energy, vol. 10, no. 2, pp. 134-148, 2023. [Online]. Available: https://www.jrenew.ir/article_175499.html.
[19].        G. A. Hamoud, "Assessment of spare transformer requirements for distribution stations," IEEE Transactions on Power Systems, vol. 26, no. 1, pp. 174-180, 2010.
[20].        G. A. Hamoud, "Use of Markov models in assessing spare transformer requirements for distribution stations," IEEE Transactions on Power Systems, vol. 27, no. 2, pp. 1098-1105, 2012.
[21].        F. Plastria, "Static competitive facility location: an overview of optimisation approaches," European Journal of Operational Research, vol. 129, no. 3, pp. 461-470, 2001.
[22].        R. Z. Farahani, S. Fallah, R. Ruiz, S. Hosseini, and N. Asgari, "OR models in urban service facility location: A critical review of applications and future developments," European journal of operational research, vol. 276, no. 1, pp. 1-27, 2019.
[23].        R. J. P. Ferreira and H. L. Ferreira, "Decision support system for location of back-up transformers based on a multi-attribute p-median model," in 2012 IEEE International Conference on Systems, Man, and Cybernetics (SMC), 2012: IEEE, pp. 629-631.
[24].        Y. K. Bichpuriya, S. A. Upadhyaya, and S. Soman, "Optimal location of spare transformers at distribution substations for reliability improvement," 2011.
[25].        W. Wangdee, W. Li, W. Shum, and P. Choudhury, "Applying probabilistic method in determining the number of spare transformers and their timing requirements," in 2007 Canadian Conference on Electrical and Computer Engineering, 2007: IEEE, pp. 137-140.
[26].        J. G. d. C. Costa and A. M. L. da Silva, "Monte Carlo simulation to assess the optimum number of distribution spare transformers," in Proceedings of the 10th International Conference on Probablistic Methods Applied to Power Systems, 2008: IEEE, pp. 1-6.
[27].        J. A. White, R. L. Francis, R. Francis, and L. F. McGinnis, Facility layout and location: An analytical approach. Prentice-Hall, 1992.